{"id":31518,"date":"2023-02-24T14:47:11","date_gmt":"2023-02-24T19:47:11","guid":{"rendered":"https:\/\/vitazan.com\/?page_id=31518"},"modified":"2023-09-22T15:40:31","modified_gmt":"2023-09-22T19:40:31","slug":"equipment","status":"publish","type":"page","link":"https:\/\/vitazan.com\/fr\/laboratory\/equipment\/","title":{"rendered":"Laboratoire \u00c9quipement"},"content":{"rendered":"\r\n<style>@media(max-width:768px){.mobile{width:50%;}}<\/style>\r\n<style>@media(max-width:768px){.mobile2 figure{width:50%;}}<\/style>\r\n\r\n\r\n\r\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\r\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" data-id=\"5328\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4855-1024x683.jpg\" alt=\"\" class=\"wp-image-5328\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4855-1024x683.jpg 1024w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4855-160x107.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4855-230x153.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4855-600x400.jpg 600w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4855-300x200.jpg 300w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4855-768x512.jpg 768w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4855.jpg 1080w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" data-id=\"5329\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4867-1024x683.jpg\" alt=\"\" class=\"wp-image-5329\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4867-1024x683.jpg 1024w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4867-160x107.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4867-230x153.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4867-600x400.jpg 600w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4867-300x200.jpg 300w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4867-768x512.jpg 768w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4867.jpg 1080w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" data-id=\"5331\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4912-1024x683.jpg\" alt=\"\" class=\"wp-image-5331\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4912-1024x683.jpg 1024w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4912-160x107.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4912-230x153.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4912-600x400.jpg 600w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4912-300x200.jpg 300w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4912-768x512.jpg 768w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/11\/IMG_4912.jpg 1080w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\r\n<\/figure>\r\n\r\n\r\n\r\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-dots\"\/>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\">Chromatographe en phase liquide \u00e0 haute performance<\/h2>\r\n\r\n\r\n\r\n<p class=\"has-medium-font-size\">Quatre CLHP<\/p>\r\n\r\n\r\n<div class=\"wp-block-image mobile\">\r\n<figure class=\"alignleft size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"225\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2136278-edited-300x225.jpg\" alt=\"\" class=\"wp-image-3495\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2136278-edited-300x225.jpg 300w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2136278-edited-160x120.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2136278-edited-230x173.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2136278-edited-320x240.jpg 320w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2136278-edited.jpg 500w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\r\n<\/div>\r\n\r\n<p style=\"text-align: justify;\"><span style=\"font-size: 14pt;\">La CLHP est un ma\u00eetre sp\u00e9cialiste de la d\u00e9termination de l\u2019identit\u00e9 et de la quantit\u00e9 d\u2019\u00e9l\u00e9ments et de mol\u00e9cules, tels que l\u2019activit\u00e9 dans une herbe, le produit d\u2019une r\u00e9action enzymatique, ou toute mol\u00e9cule qui absorbe la lumi\u00e8re ou qui peut \u00eatre rendue chromophore (capable d\u2019absorber \/ transmettre lumi\u00e8re). La HPLC est tr\u00e8s sp\u00e9cifique en ce qu\u2019elle permet de d\u00e9terminer absolument ce qu\u2019est une substance et sa quantit\u00e9 exacte. La CLHP fonctionne en injectant automatiquement un petit volume d\u2019\u00e9chantillon liquide dans une colonne remplie de particules de 1\u204420 d\u2019\u00e9paisseur d\u2019une feuille de papier blanc. L\u2019\u00e9chantillon liquide est forc\u00e9 \u00e0 travers la colonne par de puissantes micropompes. Le d\u00e9tecteur envoie un signal num\u00e9rique \u00e0 l\u2019ordinateur, o\u00f9 un logiciel sp\u00e9cialis\u00e9 est utilis\u00e9 pour identifier et d\u00e9terminer la quantit\u00e9 des composants s\u00e9par\u00e9s. Nous l\u2019utilisons r\u00e9guli\u00e8rement pour analyser la composition de compos\u00e9s pr\u00e9sents dans des m\u00e9langes complexes, tels que les vitamines hydrosolubles et liposolubles. Nous utilisons \u00e9galement la HPLC pour analyser une grande vari\u00e9t\u00e9 d\u2019ingr\u00e9dients, par exemple l\u2019astragale, le pissenlit et le tr\u00e8fle rouge. Il s\u2019agit d\u2019un chromatogramme liquide typique de vitamines hydrosolubles; on les appelle des pics chromatographiques, et chacun repr\u00e9sente un compos\u00e9 s\u00e9par\u00e9.<\/span><\/p>\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2023\/03\/Vitamin-mix-chromatogram-edited.jpg\" alt=\"\" class=\"wp-image-41610\"\/><\/figure>\r\n\r\n\r\n\r\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-dots\" id=\"UHPLCs\"\/>\r\n\r\n\r\n\r\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\r\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\r\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-dots\"\/>\r\n\r\n\r\n\r\n<h2 class=\"has-text-align-center wp-block-heading\">CLUHP<\/h2>\r\n\r\n\r\n\r\n<p class=\"has-text-align-center has-medium-font-size\">Chromatographie liquide ultra haute performance<\/p>\r\n\r\n\r\n\r\n<p class=\"has-text-align-center has-medium-font-size\">Nous avons ajout\u00e9 4 CLUHP \u00e0 notre laboratoire. <br> Ceux-ci \u00e9tendent notre vaste capacit\u00e9 de test.<\/p>\r\n<\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\r\n<figure class=\"aligncenter is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/uhplc.png\" alt=\"\" class=\"wp-image-3498\" width=\"316\" height=\"316\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/uhplc.png 421w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/uhplc-160x160.png 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/uhplc-230x230.png 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/uhplc-320x320.png 320w\" sizes=\"auto, (max-width: 316px) 100vw, 316px\" \/><\/figure>\r\n<\/div>\r\n\r\n\r\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-dots\" id=\"PCR\"\/>\r\n<\/div>\r\n<\/div>\r\n\r\n\r\n\r\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-dots\"\/>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\">Cycleur PCR: Identification ADN OGM<\/h2>\r\n\r\n\r\n\r\n<p class=\"has-medium-font-size\">Notre laboratoire a \u00e9galement ajout\u00e9 une capacit\u00e9 d\u2019extraction et d\u2019analyse d\u2019ADN. Gr\u00e2ce \u00e0 cette capacit\u00e9, nous pouvons identifier si un ingr\u00e9dient contient de l\u2019ADN ou des prot\u00e9ines OGM.<\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-2 is-layout-flex wp-block-gallery-is-layout-flex\">\r\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"665\" height=\"374\" data-id=\"3500\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/non_gmo-1.jpg\" alt=\"\" class=\"wp-image-3500\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/non_gmo-1.jpg 665w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/non_gmo-1-160x90.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/non_gmo-1-230x129.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/non_gmo-1-600x337.jpg 600w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/non_gmo-1-300x169.jpg 300w\" sizes=\"auto, (max-width: 665px) 100vw, 665px\" \/><figcaption class=\"wp-element-caption\">QUANTIFICATION DE L\u2019ADN<\/figcaption><\/figure>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"665\" height=\"374\" data-id=\"3502\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/non_gmo-3.jpg\" alt=\"\" class=\"wp-image-3502\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/non_gmo-3.jpg 665w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/non_gmo-3-160x90.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/non_gmo-3-230x129.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/non_gmo-3-600x337.jpg 600w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/non_gmo-3-300x169.jpg 300w\" sizes=\"auto, (max-width: 665px) 100vw, 665px\" \/><figcaption class=\"wp-element-caption\">PCR EN TEMPS REEL (qPCR)<\/figcaption><\/figure>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"665\" height=\"374\" data-id=\"3501\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/non_gmo-2.jpg\" alt=\"\" class=\"wp-image-3501\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/non_gmo-2.jpg 665w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/non_gmo-2-160x90.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/non_gmo-2-230x129.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/non_gmo-2-600x337.jpg 600w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/non_gmo-2-300x169.jpg 300w\" sizes=\"auto, (max-width: 665px) 100vw, 665px\" \/><figcaption class=\"wp-element-caption\">EXTRACTION\/PURIFICATION DE L\u2019ADN<\/figcaption><\/figure>\r\n<\/figure>\r\n\r\n\r\n\r\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-dots\" id=\"UPLC\"\/>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\">CLUP\/SM\/SM (CL\/SM \u2014 triple quadrip\u00f4le)<\/h2>\r\n\r\n\r\n\r\n<p class=\"has-medium-font-size\">Spectrom\u00e9trie de masse par chromatographie liquide \u00e0 ultra-haute performance \u2014 D\u00e9tecteur double de spectrom\u00e9trie de masse par chromatographie liquide \u00e0 ultra-haute performance<\/p>\r\n\r\n\r\n<div class=\"wp-block-image mobile\">\r\n<figure class=\"alignleft size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186293-edited.jpg\" alt=\"\" class=\"wp-image-3504\" width=\"250\" height=\"334\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186293-edited.jpg 500w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186293-edited-120x160.jpg 120w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186293-edited-230x307.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186293-edited-320x427.jpg 320w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186293-edited-225x300.jpg 225w\" sizes=\"auto, (max-width: 250px) 100vw, 250px\" \/><\/figure>\r\n<\/div>\r\n\r\n\r\n<p style=\"text-align: justify;\">Si la CLHP est le ma\u00eetre sp\u00e9cialiste de l\u2019identification et de la quantification, alors la LC-MS \/ MS est la star. Elle est capable de faire tout ce que la CLHP peut faire, mais mieux et plus pr\u00e9cis\u00e9ment. Pour ce faire, elle utilise une micropompe \u00e0 tr\u00e8s haute pression (15 000 psi), combin\u00e9e \u00e0 un r\u00e9seau double d\u00e9tecteur \/ photodiode (PDA) et un d\u00e9tecteur de spectrom\u00e8tre de masse plus puissant. Elle est utilis\u00e9e dans les cas o\u00f9 une sensibilit\u00e9 extr\u00eame est n\u00e9cessaire. Elle s\u2019agit actuellement de l\u2019outil d\u2019analyse laplus avanc\u00e9e et la plus \u00e9tendue. Elle permet les mesures les plus pr\u00e9cises, en parties par billion plut\u00f4t qu\u2019en milliards ou en millions\u2026 La LC-MS \/ MS est capable d\u2019analyser efficacement les herbes et les composants m\u00e9dicinaux. La LC \/ MS combine les capacit\u00e9s de s\u00e9paration avanc\u00e9es d\u2019une CLHP avec les puissantes capacit\u00e9s analytiques d\u2019un spectrom\u00e8tre de masse. Un \u00e9chantillon est inject\u00e9 dans le syst\u00e8me UPLC et s\u00e9par\u00e9 en ses diff\u00e9rents composants. Ces composants p\u00e9n\u00e8trent dans le MS via une \u00abinterface d\u2019\u00e9lectro-pulv\u00e9risation\u00bb, o\u00f9 une ionisation tr\u00e8s rapide a lieu. \u00c0 ce stade, les spectres de masse des composants peuvent \u00eatre utilis\u00e9s pour localiser pr\u00e9cis\u00e9ment l\u2019analyse de l\u2019\u00e9chantillon. Le principal avantage de ce syst\u00e8me est qu\u2019il g\u00e9n\u00e8re des mesures rapides, pr\u00e9cises et extr\u00eamement pr\u00e9cises en cr\u00e9ant une signature \u00e9lectronique d\u2019un compos\u00e9. Nous testons de nombreux nutraceutiques avec cet instrument, tels que les glycosides dans l\u2019act\u00e9e \u00e0 grappes noires, la thuyone dans le bois de ver et les antibiotiques r\u00e9siduels dans la gel\u00e9e royale.<\/p>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\" id=\"GC-FID\">Deux CG-FID\/SM<\/h2>\r\n\r\n\r\n\r\n\r\n<p class=\"has-medium-font-size\">Chromatographe en phase gazeuse \u2014 d\u00e9tecteur \u00e0 ionisation de flamme\/spectrom\u00e8tre de masse<\/p>\r\n\r\n\r\n<div class=\"wp-block-image mobile2\">\r\n<figure class=\"alignright size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186302-edited.jpg\" alt=\"\" class=\"wp-image-3505\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186302-edited.jpg 500w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186302-edited-160x120.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186302-edited-230x173.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186302-edited-320x240.jpg 320w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186302-edited-300x225.jpg 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><figcaption class=\"wp-element-caption\">2 pcs GC-FID\/MSs<\/figcaption><\/figure>\r\n<\/div>\r\n\r\n<p style=\"text-align: justify;\">Le GC est utilis\u00e9 pour analyser les mol\u00e9cules volatiles \u00e0 haut point de fusion, comme les acides gras dans l\u2019huile de poisson. De plus, les \u00e9chantillons soumis au GC n\u2019ont pas besoin de solvants ni de \u00abphase mobile liquide\u00bb; au lieu de cela, les \u00e9chantillons sont transport\u00e9s par un gaz inerte \u00e0 travers le syst\u00e8me. Par cons\u00e9quent, si nous recherchons des solvants, l\u2019instrument de choix est le GC-FID \/ MS; aucune \u00e9tape n\u2019est n\u00e9cessaire pour \u00e9liminer les solvants utilis\u00e9s pour pr\u00e9parer l\u2019\u00e9chantillon. GC-MS est pr\u00e9cis\u00e9ment capable d\u2019identifier et de d\u00e9terminer la quantit\u00e9 de mol\u00e9cules d\u2019int\u00e9r\u00eat, tandis que GC-FID n\u2019est utilis\u00e9 que pour d\u00e9terminer la quantit\u00e9 de mol\u00e9cules. Comme LC-MS \/ MS, GC-MS est \u00e9galement capable de cr\u00e9er une signature \u00e9lectronique d\u2019une mol\u00e9cule. La complexit\u00e9 de l\u2019ex\u00e9cution du test dictera quel instrument sera utilis\u00e9. Dans un syst\u00e8me GC, l\u2019\u00e9chantillon vaporis\u00e9 est d\u00e9plac\u00e9 avec un gaz vecteur \u00e0 travers une colonne capillaire sp\u00e9cialement rev\u00eatue. La colonne s\u00e9pare les composants avant d\u2019entrer dans le d\u00e9tecteur; dans notre cas, soit le FID soit le MS, selon l\u2019application. Nous utilisons \u00e9galement le syst\u00e8me GC-FID pour d\u00e9terminer la quantit\u00e9 d\u2019acides gras communs et d\u2019huiles essentielles pr\u00e9sentes dans les huiles telles que le tamanu, l\u2019arganier et l\u2019huile de poisson. Il s\u2019agit d\u2019un chromatogramme typique des acides gras d\u2019un \u00e9chantillon d\u2019huile d\u2019argan.<\/p>\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1271\" height=\"742\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Argan-oil-chromatogram.jpg\" alt=\"\" class=\"wp-image-3506\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Argan-oil-chromatogram.jpg 1271w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Argan-oil-chromatogram-160x93.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Argan-oil-chromatogram-230x134.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Argan-oil-chromatogram-600x350.jpg 600w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Argan-oil-chromatogram-300x175.jpg 300w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Argan-oil-chromatogram-768x448.jpg 768w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Argan-oil-chromatogram-1024x598.jpg 1024w\" sizes=\"auto, (max-width: 1271px) 100vw, 1271px\" \/><\/figure>\r\n\r\n\r\n<p style=\"text-align: justify;\">Les PCB et les pesticides sont test\u00e9s par le GC-MS. Au fur et \u00e0 mesure que les \u00e9chantillons traversent la chambre d\u2019ionisation, ils sont bombard\u00e9s d\u2019une tr\u00e8s haute tension \u00e9lectrique qui entra\u00eene une fragmentation (s\u00e9paration) compl\u00e8te des compos\u00e9s individuels. Les fragments sont reconstruits lorsqu\u2019ils se d\u00e9placent \u00e0 travers un tube \u00e0 vide selon leur rapport masse \/ charge. Le signal donn\u00e9 est enregistr\u00e9 par l\u2019ordinateur pour analyse. Les compos\u00e9s sont compar\u00e9s \u00e0 une biblioth\u00e8que bien connue du National Institute of Standards and Technology (NIST) ou \u00e0 un mat\u00e9riau standard de r\u00e9f\u00e9rence certifi\u00e9. Le chromatogramme ionique total ci-dessous repr\u00e9sente un m\u00e9lange de pesticides.<\/p>\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1277\" height=\"897\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Pesticides-chromatogram.jpg\" alt=\"\" class=\"wp-image-3507\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Pesticides-chromatogram.jpg 1277w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Pesticides-chromatogram-160x112.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Pesticides-chromatogram-230x162.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Pesticides-chromatogram-600x421.jpg 600w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Pesticides-chromatogram-300x211.jpg 300w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Pesticides-chromatogram-768x539.jpg 768w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Pesticides-chromatogram-1024x719.jpg 1024w\" sizes=\"auto, (max-width: 1277px) 100vw, 1277px\" \/><\/figure>\r\n\r\n\r\n\r\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-dots\"\/>\r\n\r\n\r\n<p style=\"text-align: justify;\">Les \u00e9chantillons test\u00e9s pour les solvants passent par notre espace de t\u00eate GC-FID. Le FID incin\u00e8re l\u2019\u00e9chantillon, donnant un signal \u00e9lectrique pour l\u2019analyse. Nous utilisons cette configuration pour d\u00e9tecter s\u2019il existe des solvants, tels que le 1,2-dichloro\u00e9thane et le 1,1,1-trichloro\u00e9thane, qui sont des canc\u00e9rog\u00e8nes connus pour l\u2019homme. Ces contaminants peuvent \u00eatre pr\u00e9sents dans des extraits de plantes de mauvaise qualit\u00e9, et nous n\u2019avons aucune tol\u00e9rance pour eux. Le chromatogramme ci-dessous repr\u00e9sente le solvant r\u00e9siduel.\u00a0<\/p>\r\n\r\n\r\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"598\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/residual-solvents-chromatogram-2-1024x598.jpg\" alt=\"\" class=\"wp-image-3510\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/residual-solvents-chromatogram-2-1024x598.jpg 1024w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/residual-solvents-chromatogram-2-160x93.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/residual-solvents-chromatogram-2-230x134.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/residual-solvents-chromatogram-2-600x350.jpg 600w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/residual-solvents-chromatogram-2-300x175.jpg 300w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/residual-solvents-chromatogram-2-768x448.jpg 768w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/residual-solvents-chromatogram-2.jpg 1273w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\" id=\"ICP-OES\">ICP-OES<\/h2>\r\n\r\n\r\n\r\n<p class=\"has-medium-font-size\">Spectroscope d\u2019\u00e9mission optique \u00e0 plasma \u00e0 couplage inductif<\/p>\r\n\r\n\r\n<div class=\"wp-block-image mobile2\">\r\n<figure class=\"alignright size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P6036513-edited.jpg\" alt=\"\" class=\"wp-image-3511\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P6036513-edited.jpg 500w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P6036513-edited-160x120.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P6036513-edited-230x173.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P6036513-edited-320x240.jpg 320w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P6036513-edited-300x225.jpg 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\r\n<\/div>\r\n\r\n<p style=\"text-align: justify;\">ICP est sp\u00e9cialis\u00e9 dans l\u2019analyse des m\u00e9taux et min\u00e9raux. Avec cet appareil, nous pouvons d\u00e9terminer efficacement et pr\u00e9cis\u00e9ment l\u2019identit\u00e9 et la quantit\u00e9 de tout m\u00e9tal pr\u00e9sent dans un \u00e9chantillon, qu\u2019il s\u2019agisse de fer, de magn\u00e9sium, de plomb, de mercure ou de bore. Le processus pour tester ces m\u00e9taux est beaucoup plus simple qu\u2019il ne le serait sur la CLHP ou la LC \/ MS. Avec un ICP-OES, un \u00e9chantillon s\u2019\u00e9coule dans une torche \u00e0 plasma, o\u00f9 il est incin\u00e9r\u00e9 en particules atomis\u00e9es. Les \u00e9lectrons de l\u2019\u00e9chantillon atomis\u00e9 passent par diff\u00e9rents niveaux d\u2019\u00e9nergie et, ce faisant, les atomes \u00e9mettent de la lumi\u00e8re; cette lumi\u00e8re est analys\u00e9e pour des informations significatives. Nous l\u2019utilisons pour d\u00e9tecter la contamination par des m\u00e9taux traces de faible niveau, notamment le mercure, l\u2019arsenic, le plomb et le cadmium. Ces contaminants impr\u00e8gnent la cro\u00fbte terrestre et peuvent \u00eatre particuli\u00e8rement pr\u00e9sents dans les aliments cultiv\u00e9s dans le sol ou tout \u00e9l\u00e9ment provenant de la terre. Essentiellement, les seuls restes d\u2019un \u00e9chantillon atomis\u00e9 seront des m\u00e9taux r\u00e9siduels, que nous pourrons ensuite d\u00e9tecter. Cela rend les m\u00e9thodes d\u00e9velopp\u00e9es pour tester les m\u00e9taux plus faciles \u00e0 ex\u00e9cuter sur l\u2019ICP. Voici une capture d\u2019\u00e9cran ICP de la vue spectrale du cadmium.<\/p>\r\n\r\n\r\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-dots\"\/>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1140\" height=\"645\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Cd-228.jpg\" alt=\"\" class=\"wp-image-3512\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Cd-228.jpg 1140w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Cd-228-160x91.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Cd-228-230x130.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Cd-228-600x339.jpg 600w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Cd-228-300x170.jpg 300w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Cd-228-768x435.jpg 768w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Cd-228-1024x579.jpg 1024w\" sizes=\"auto, (max-width: 1140px) 100vw, 1140px\" \/><\/figure>\r\n\r\n\r\n\r\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-dots\" id=\"Spectrophotometers\"\/>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\">Spectophotom\u00e8res<\/h2>\r\n\r\n\r\n<div class=\"wp-block-image mobile2\">\r\n<figure class=\"alignright size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186306-edited.jpg\" alt=\"\" class=\"wp-image-3513\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186306-edited.jpg 500w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186306-edited-160x120.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186306-edited-230x173.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186306-edited-320x240.jpg 320w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186306-edited-300x225.jpg 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\r\n<\/div>\r\n\r\n<p style=\"text-align: justify;\">Le spectrophotom\u00e8tre est un outil \u00e9conomique qui peut \u00eatre utilis\u00e9 pour d\u00e9terminer la quantit\u00e9 d\u2019\u00e9chantillons qui absorbent ou transmettent la lumi\u00e8re. Sur la base de l\u2019absorption ou de la transmission de la lumi\u00e8re, une corr\u00e9lation peut \u00eatre \u00e9tablie pour d\u00e9terminer la quantit\u00e9 d\u2019une substance. L\u2019identit\u00e9 de l\u2019\u00e9chantillon sera d\u00e9termin\u00e9e par d\u2019autres instruments. Un spectrophotom\u00e8tre est un appareil utilis\u00e9 pour mesurer l\u2019intensit\u00e9 lumineuse. La NASA comprend g\u00e9n\u00e9ralement un spectrophotom\u00e8tre sur ses atterrisseurs interplan\u00e9taires tels que les rovers Spirit et Opportunity. Un petit faisceau de lumi\u00e8re traverse l\u2019\u00e9chantillon; une partie de la lumi\u00e8re est absorb\u00e9e, mais ce qui passe est d\u00e9tect\u00e9 et mesur\u00e9 par le spectrophotom\u00e8tre. Nous pouvons utiliser ces informations pour d\u00e9terminer la quantit\u00e9 d\u2019une substance. Notre spectrophotom\u00e8tre est utilis\u00e9 pour d\u00e9terminer certaines activit\u00e9s enzymatiques, telles que la papa\u00efne et la brom\u00e9la\u00efne, ou la teneur en anthocyanidines de la myrtille. Voici une capture d\u2019\u00e9cran d\u2019un graphique spectrophotom\u00e9trique d\u2019un \u00e9chantillon de papa\u00efne.<\/p>\r\n\r\n\r\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/SOD-enzymantic-assay.jpg\" alt=\"\" class=\"wp-image-3514\" width=\"1140\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/SOD-enzymantic-assay.jpg 818w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/SOD-enzymantic-assay-160x31.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/SOD-enzymantic-assay-230x45.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/SOD-enzymantic-assay-600x117.jpg 600w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/SOD-enzymantic-assay-300x58.jpg 300w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/SOD-enzymantic-assay-768x149.jpg 768w\" sizes=\"(max-width: 818px) 100vw, 818px\" \/><\/figure>\r\n\r\n\r\n\r\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-dots\" id=\"HPTLC\"\/>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\">CCMHP<\/h2>\r\n\r\n\r\n\r\n<p class=\"has-medium-font-size\">Chromatographe en couche mince de haute pr\u00e9cision<\/p>\r\n\r\n\r\n<div class=\"wp-block-image mobile\">\r\n<figure class=\"alignleft size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P6046523-edited.jpg\" alt=\"\" class=\"wp-image-3515\" width=\"375\" height=\"500\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P6046523-edited.jpg 500w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P6046523-edited-120x160.jpg 120w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P6046523-edited-230x307.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P6046523-edited-320x427.jpg 320w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P6046523-edited-225x300.jpg 225w\" sizes=\"auto, (max-width: 375px) 100vw, 375px\" \/><\/figure>\r\n<\/div>\r\n\r\n<p style=\"text-align: justify;\">La CCMHP est un outil efficace pour v\u00e9rifier l\u2019empreinte digitale de l\u2019identit\u00e9 des ingr\u00e9dients par rapport \u00e0 une plaque de r\u00e9f\u00e9rence. Nous sommes en mesure de confirmer le profil d\u2019une plante gr\u00e2ce \u00e0 cet outil et de nous assurer que le bon ingr\u00e9dient est utilis\u00e9. Avec une CCMHP, les composants individuels d\u2019un m\u00e9lange sont s\u00e9par\u00e9s sur une fine plaque rev\u00eatue de verre, qui est ensuite plac\u00e9e dans une chambre de d\u00e9veloppement. La plaque CCM est plac\u00e9e sous une lampe ultraviolette et les bandes des diff\u00e9rents composants sont visualis\u00e9es. Contrairement \u00e0 un CCM standard, avec une CCMHP, de nombreuses t\u00e2ches sont automatis\u00e9es via la robotique, \u00e9liminant l\u2019incertitude des \u00e9chantillons appliqu\u00e9s aux plaques \u00e0 la main. Nous utilisons le CCMHP pour d\u00e9tecter si des produits ont \u00e9t\u00e9 contamin\u00e9s par des mycotoxines, une classe dangereuse de toxines qui peuvent se d\u00e9velopper sur la mati\u00e8re v\u00e9g\u00e9tale dans des conditions humides. Vous pouvez voir une plaque CCMHP ci-dessous:<\/p>\r\n\r\n<div class=\"wp-block-image\">\r\n<figure class=\"alignright size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"206\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/CAMAG_Produktekatalog_HG_14_15_high_bearbeitet-2.png\" alt=\"\" class=\"wp-image-3516\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/CAMAG_Produktekatalog_HG_14_15_high_bearbeitet-2.png 500w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/CAMAG_Produktekatalog_HG_14_15_high_bearbeitet-2-160x66.png 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/CAMAG_Produktekatalog_HG_14_15_high_bearbeitet-2-230x95.png 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/CAMAG_Produktekatalog_HG_14_15_high_bearbeitet-2-320x132.png 320w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/CAMAG_Produktekatalog_HG_14_15_high_bearbeitet-2-300x124.png 300w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/CAMAG_Produktekatalog_HG_14_15_high_bearbeitet-2-240x100.png 240w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\r\n<\/div>\r\n\r\n\r\n<hr class=\"wp-block-separator alignfull has-alpha-channel-opacity is-style-dots\" id=\"NIR\"\/>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\">SPIR<\/h2>\r\n\r\n\r\n\r\n<p class=\"has-medium-font-size\">Spectrom\u00e8tre proche-infrarouge<\/p>\r\n\r\n\r\n<div class=\"wp-block-image mobile2\">\r\n<figure class=\"alignright size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"375\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186300-edited.jpg\" alt=\"\" class=\"wp-image-3517\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186300-edited.jpg 500w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186300-edited-160x120.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186300-edited-230x173.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186300-edited-320x240.jpg 320w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P2186300-edited-300x225.jpg 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\r\n<\/div>\r\n\r\n<p style=\"text-align: justify;\">Le NIR peut \u00eatre utilis\u00e9 pour tester une grande vari\u00e9t\u00e9 de substances; herbes et isolats tels que les acides amin\u00e9s. Le NIR peut tester presque n\u2019importe quoi, tant que nous avons un \u00e9chantillon connu pour \u00eatre cette substance. Avec cet appareil, nous pouvons garantir la fra\u00eecheur des plantes que nous utilisons dans votre produit. Le NIR fonctionne en comparant l\u2019empreinte digitale d\u2019une substance avec une moyenne d\u2019empreintes digitales d\u2019\u00e9chantillons connus pour \u00eatre cette substance. Ces empreintes digitales forment un mod\u00e8le de r\u00e9f\u00e9rence 3D de ce qui est acceptable. Ceci est important, car m\u00eame cultiv\u00e9e dans des conditions similaires, la m\u00eame plante ne poussera pas de fa\u00e7on identique. NIR nous permet d\u2019identifier la qualit\u00e9 totale des produits \u00e0 base de plantes. Nous nous assurons que seuls les \u00e9chantillons qui r\u00e9pondent \u00e0 nos crit\u00e8res stricts de fra\u00eecheur et de qualit\u00e9 peuvent passer. Nous incluons uniquement les plantes herbac\u00e9es de la plus haute qualit\u00e9 dans les mod\u00e8les de r\u00e9f\u00e9rence que nous cr\u00e9ons pour le NIR. Le NIR permet une identification fiable d\u2019un \u00e9chantillon en comparant ses spectres aux spectres d\u2019un \u00e9chantillon de caract\u00e9ristiques connues. Le NIR analyse les propri\u00e9t\u00e9s transmissives de longueurs d\u2019onde sp\u00e9cifiques de la lumi\u00e8re dans l\u2019\u00e9chantillon mesur\u00e9. Voici une repr\u00e9sentation des informations spectrales dans une image tridimensionnelle.<\/p>\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"823\" height=\"592\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Picture9-2.jpg\" alt=\"\" class=\"wp-image-3520\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Picture9-2.jpg 823w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Picture9-2-160x115.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Picture9-2-230x165.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Picture9-2-600x432.jpg 600w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Picture9-2-300x216.jpg 300w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Picture9-2-768x552.jpg 768w\" sizes=\"auto, (max-width: 823px) 100vw, 823px\" \/><\/figure>\r\n\r\n\r\n\r\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-dots\" id=\"Microscope\"\/>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\">Microscope<\/h2>\r\n\r\n\r\n<div class=\"wp-block-image mobile2\">\r\n<figure class=\"alignright size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P6036507-edited.jpg\" alt=\"\" class=\"wp-image-3521\" width=\"250\" height=\"334\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P6036507-edited.jpg 500w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P6036507-edited-120x160.jpg 120w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P6036507-edited-230x307.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P6036507-edited-320x427.jpg 320w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/P6036507-edited-225x300.jpg 225w\" sizes=\"auto, (max-width: 250px) 100vw, 250px\" \/><\/figure>\r\n<\/div>\r\n\r\n<p style=\"text-align: justify;\">Le microscope v\u00e9n\u00e9rable est toujours un aliment de base dans n\u2019importe quel laboratoire. Bien s\u00fbr, nous utilisons un microscope optique moderne; ce style de microscope utilise un faisceau de lumi\u00e8re focalis\u00e9 qui est converg\u00e9 par la lentille du condenseur sur un point sp\u00e9cifique de l\u2019\u00e9chantillon. Nous l\u2019utilisons pour examiner le statut cellulaire cass\u00e9 des \u00e9chantillons de <i>Chlorella<\/i>. Voici un exemple d\u2019une paroi cellulaire cass\u00e9e dans un \u00e9chantillon de <i>Chlorella<\/i>; les parois cellulaires bris\u00e9es facilitent la digestion et l\u2019absorption.<\/p>\r\n\r\n\r\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Chlorella-picture-1-1024x768.jpg\" alt=\"\" class=\"wp-image-3522\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Chlorella-picture-1-1024x768.jpg 1024w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Chlorella-picture-1-160x120.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Chlorella-picture-1-230x173.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Chlorella-picture-1-600x450.jpg 600w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Chlorella-picture-1-300x225.jpg 300w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Chlorella-picture-1-768x576.jpg 768w, https:\/\/vitazan.com\/wp-content\/uploads\/2018\/11\/Chlorella-picture-1.jpg 1600w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\r\n\r\n\r\n\r\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-dots\" id=\"ICP-MS\"\/>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><strong>NexION\u00ae 2000 ICP-MS<\/strong><\/h2>\r\n\r\n\r\n<p style=\"text-align: justify;\">Le spectrom\u00e8tre de masse \u00e0 plasma \u00e0 couplage inductif NexION 2000 (ICP-MS) est tr\u00e8s polyvalent. Il dispose d\u2019une gamme de technologies uniques qui se combinent pour offrir les meilleures performances quel que soit le d\u00e9fi analytique. Sa polyvalence permet de manipuler facilement n\u2019importe quelle matrice d\u2019\u00e9chantillons et de traiter toutes les interf\u00e9rences; Il mesure avec pr\u00e9cision les niveaux infimes (sous-ppt) d\u2019oligo-\u00e9l\u00e9ments essentiels tels que Na, K, Ca et Fe. Il est coupl\u00e9 \u00e0 un prepFAST MC &#x2122; qui est un syst\u00e8me de chromatographie \u00e0 basse pression enti\u00e8rement automatis\u00e9 qui isole les \u00e9l\u00e9ments d\u2019int\u00e9r\u00eat de la matrice de l\u2019\u00e9chantillon, et recueille plusieurs fractions distinctes d\u2019\u00e9luant pour une analyse isotopique pr\u00e9cise. Cela permet par exemple de s\u00e9parer l\u2019arsenic organique de l\u2019arsenic inorganique.<\/p>\r\n\r\n\r\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-3 is-layout-flex wp-block-gallery-is-layout-flex\">\r\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"468\" height=\"312\" data-id=\"5227\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2020\/10\/nex.jpg\" alt=\"\" class=\"wp-image-5227\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2020\/10\/nex.jpg 468w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/10\/nex-160x107.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/10\/nex-230x153.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/10\/nex-320x213.jpg 320w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/10\/nex-300x200.jpg 300w\" sizes=\"auto, (max-width: 468px) 100vw, 468px\" \/><\/figure>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"468\" height=\"307\" data-id=\"5228\" src=\"https:\/\/vitazan.com\/wp-content\/uploads\/2020\/10\/nex2.jpg\" alt=\"\" class=\"wp-image-5228\" srcset=\"https:\/\/vitazan.com\/wp-content\/uploads\/2020\/10\/nex2.jpg 468w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/10\/nex2-160x105.jpg 160w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/10\/nex2-230x151.jpg 230w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/10\/nex2-320x210.jpg 320w, https:\/\/vitazan.com\/wp-content\/uploads\/2020\/10\/nex2-300x197.jpg 300w\" sizes=\"auto, (max-width: 468px) 100vw, 468px\" \/><\/figure>\r\n<\/figure>\r\n\r\n\r\n\r\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-dots\"\/>\r\n\r\n\r\n\r\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-a89b3969 wp-block-buttons-is-layout-flex\">\r\n<div class=\"wp-block-button is-style-outline is-style-outline--4\" style='margin:20px 50px 0;'><a class=\"wp-block-button__link has-header-gradient-color has-text-color wp-element-button\" href=\"\/laboratory\/\"><strong>Laboratoire accr\u00e9dit\u00e9<\/strong><\/a><\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-button is-style-outline is-style-outline--5\" style='margin:20px 50px 0;'><a class=\"wp-block-button__link has-header-gradient-color has-text-color wp-element-button\" href=\"\/testing\/\"><strong>Tests analytiques<\/strong><\/a><\/div>\r\n<\/div>\r\n\r\n\r\n\r\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-dots\"\/>\r\n","protected":false},"excerpt":{"rendered":"<p>Chromatographe en phase liquide \u00e0 haute performance Quatre CLHP La CLHP est un ma\u00eetre sp\u00e9cialiste de la d\u00e9termination de l\u2019identit\u00e9 et de la quantit\u00e9 d\u2019\u00e9l\u00e9ments et de mol\u00e9cules, tels que l\u2019activit\u00e9 dans une herbe, le produit d\u2019une r\u00e9action enzymatique, ou toute mol\u00e9cule qui absorbe la lumi\u00e8re ou qui peut \u00eatre [&hellip;]<\/p>\n","protected":false},"author":1122,"featured_media":0,"parent":6980,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/template-fullwidth.php","meta":{"_acf_changed":false,"_editorskit_title_hidden":false,"_editorskit_reading_time":0,"_editorskit_is_block_options_detached":false,"_editorskit_block_options_position":"{}","_eb_attr":"","footnotes":""},"class_list":["post-31518","page","type-page","status-publish","hentry"],"acf":[],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/vitazan.com\/fr\/wp-json\/wp\/v2\/pages\/31518","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vitazan.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vitazan.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/vitazan.com\/fr\/wp-json\/wp\/v2\/users\/1122"}],"replies":[{"embeddable":true,"href":"https:\/\/vitazan.com\/fr\/wp-json\/wp\/v2\/comments?post=31518"}],"version-history":[{"count":5,"href":"https:\/\/vitazan.com\/fr\/wp-json\/wp\/v2\/pages\/31518\/revisions"}],"predecessor-version":[{"id":33924,"href":"https:\/\/vitazan.com\/fr\/wp-json\/wp\/v2\/pages\/31518\/revisions\/33924"}],"up":[{"embeddable":true,"href":"https:\/\/vitazan.com\/fr\/wp-json\/wp\/v2\/pages\/6980"}],"wp:attachment":[{"href":"https:\/\/vitazan.com\/fr\/wp-json\/wp\/v2\/media?parent=31518"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}